How To: Set Expected Fan Speed And Temperature Ranges

Updated

Tell Foreman what normal looks like for your miners' fan speed and temperature. Miners outside the range show a warning or failure on the Issues page, and can send an alert.

Before You Start

  • You need the Edit Miners permission.
  • Use the Miners page in table view. Bulk Edit isn't available in card view.
  • Expected ranges differ by model and cooling, so set them per miner type.

Steps

  1. Go to Miners and filter to one miner type.
  2. Click Bulk Edit Miners, select the miners (the first checkbox selects all), and click Edit (#).
  3. Choose the range to set, for example Expected Fan Speed Range (Low) or Expected Temperature Range.
  4. Turn on Toggle Alerting.
  5. Drag the sliders to set where a warning starts and where an error starts. For example, to flag fans below 5,000 RPM, set Warn Less Than and Error Less Than to meet at 5,000.
  6. Click Apply.

Expected Fan Speed Range (Low) option in Bulk Edit

Sliders for the warning and error thresholds

What You Should See

In the Miners table, hover over the Max Fan or Max Temp value to see the range. Miners outside it show a fan or temperature issue on the Issues page.

Notes

  • Whatsminers look hotter. Whatsminers report chip temperatures, which run hotter than the board temperatures that Antminers report. Set higher temperature thresholds for Whatsminers so they don't flag unnecessarily.
  • Get notified another way. To get alerts in Slack, Discord, Google Chat or Telegram, or to act automatically, create a trigger on the Miner Fan Speed or Miner Temperature condition. See Quick Guide: Alerts & Triggers.

Last verified: November 19, 2026