Quick Guide: Infrastructure - Modbus Devices

Updated

Managing power efficiently is one of the most important parts of running a mining operation. While Smart PDUs give device-level visibility, they don’t always capture the full picture of site-level or circuit-level power usage. This is where Modbus devices come in.

 

What is a Modbus Device?

Unlike a single standalone unit, Modbus is a communication standard (protocol) that enables data exchange between electrical monitoring devices and management systems. These devices can be both read from and written to, allowing Foreman to collect real-time data and send commands back when needed.

In mining, Modbus devices are typically electrical meters installed at the circuit, panel, or site level. They capture energy usage data and report it digitally using the Modbus protocol — a widely adopted standard in industrial energy monitoring.

This means you’re not limited to values reported by individual miners. Instead, you gain visibility into the true load on your electrical infrastructure.

 

What Values Do Modbus Devices Capture?

Depending on the model, Modbus-supported devices can provide metrics such as:

  • Voltage (V) – supply voltage per phase

  • Current (A) – amperage drawn through the circuit

  • Power (kW) – real-time power consumption

  • Power Factor (PF) – efficiency of power usage

  • Energy (kWh) – cumulative energy consumed

  • Frequency (Hz) – line frequency (50/60 Hz)

Because this data comes directly from your electrical system, it’s more accurate than miner firmware or nameplate estimates.

 

What Modbus Data Does in Foreman

  • Metered Site Load: a site meter's total draw shows on the Command Center and is what Setpoint dispatches hold your load against. See Quick Guide: Metered Site Load.
  • Available Power: a reading of the power available to you, which Buffered dispatches stay below. See Quick Guide: Buffered Dispatches.
  • Custom readings: any other value, such as gas pressure or a circuit's current, which can start and stop Infrastructure Initiated Dispatches or drive infrastructure triggers. See Quick Guide: Infrastructure Initiated Dispatches.
  • Live stats: every reading shows on the Infrastructure page under View Current Stats.

Set One Up

See How To: Add A Modbus Meter Or Device.

Last verified: November 23, 2026