The Infrastructure page is where you add the equipment around your miners, such as PDUs, meters, switches and cooling towers, and connect it to your Site Map. Foreman uses this information to show device stats, control devices, place miners on the Site Map automatically, balance power phases and run meter-based dispatches. Open it from Infrastructure in the left-hand menu.

Before You Start

  • View Infrastructure lets you see the page. Edit Infrastructure lets you add, edit and remove devices. External Device Control lets you send commands to devices, such as turning PDU outlets on or off. See Quick Guide: Roles And Permissions.
  • Devices are reached through a Pickaxe on the same network, so have the Pickaxe running first.

What You Can Add

KindUsed forLearn more
PDUsOutlet power control and per-outlet readings for the miners plugged into them.How To: Add And Associate APDUs
Managed switchesPlacing miners on the Site Map automatically from the switch port they're plugged into.How To: Automatically Populate Your Site Map
Meters and other Modbus devicesMetered site load, available power, and readings that can start dispatches.How To: Set Up Your Meter As Infrastructure
Cooling towersLiquid temperatures, pressures, flow and leak detection, plus power and temperature control.How To: Add Bitmain Antspace HK3 Liquid Cooling Tower To Foreman
IP Address attributePlacing miners on the Site Map from static IP addresses.How To: Generate A Site Map Using Static IP Addresses
Power Phase attributeRecording which phase each location is on, for phase-balanced curtailment.How To: Set Up Phase Balancing
Power partner devicesConnections for programs such as FCR-D, and RTAC devices for automated demand response.How To: Participate In FCR-D With Sympower

The full list of device types is in the Type menu when you add infrastructure.

Add Devices

  • One device: click Add Infrastructure, choose the type, and enter its name, Pickaxe, IP address and port.
  • Many devices: click Upload Infrastructure, choose a type and download the template. The CSV needs Name, Pickaxe Key, IP and Port; some types take extra columns. Before anything changes, Foreman shows how many items will be created, updated and deleted. With Partial Upload off, devices not in the file are deleted.

Connect Devices to the Site Map

An association links a device to Site Map groups, racks or individual locations. For example, it records which PDU outlet or switch port feeds each miner location.

  • A few at a time: use View in Site Map from a device's actions and pick locations on the map.
  • In bulk: click Upload Associations, choose the type and download the template. Each row has an Association Type (group, rack or location), the Association name (the Site Map group or rack name), an optional Identifier (such as a port, outlet or phase) and, for locations, the Location Row and Location Index.

Monitor and Control Devices

  • The table shows each device's latest stats. Use View Current Stats for a live reading, or View Details for the device's details page.
  • Use Edit or Delete from a device's actions. Deleting a device removes all its associations.
  • Select devices to send commands in bulk, such as Toggle Power or Temp Control, where the device supports them.
  • To be alerted or take action when a device reading crosses a threshold, create an infrastructure trigger. To start a dispatch from a reading, see Quick Guide: Infrastructure Initiated Dispatches.